Actisense NMEA 0183 Guía de instalación Pagina 18

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 22
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 17
432-0007-00-28-en-US v100 Integration with NMEA Devices Application Note
The ShipModul uses port number 10110, which is a registered port for NMEA data. Therefore the UDP
Terminal of the Radar Server configuration is also set up to use port 10110. Open the camera server.ini
configuration file with a text editor, as in the first example. Perform a search of the file for “Sensor 1” to
locate the section related to the UDP Terminal:
[Sensor 1: TERMINAL Configuration - Device 0]
Enabled=yes
IP Address=192.168.250.94
UDP Port=10001
UDP Local Port=10110
Local IP Address=eth0
Type=UDP Terminal
Modify the file to use the correct IP address and UDP port, save the file, and upload it to the camera with a
web browser. Stop and start the Camera Server so the new configuration settings are used.